VA 570 - Flow meter | CS Instrument Viet Nam
VA 570 - Flow meter with integrated measuring section
Special measurement technology features:
• 4 values in the display: Flow, total consumption, velocity, temperature. Units freely adjustable
• All measured values, settings like gas type, inner diameter,
serial number and so on retrievable via Modbus RTU
• Comprehensive diagnosis functions readable at the display
or remote access via Modbus like e. g. exceeding of max/min
values °C, calibration cycle, error codes, serial number
• Notification in case of exceeding of the calibration cycle
• Standard version accuracy 1.5 % of m.v. ± 0.3 % of f.s.
• Precision version accuracy 1.0 % of m.v. ± 0.3 % of f.s.
• Measuring span of 1 : 1000 (0.1 up to 224 m/s)
• Configuration and diagnosis via display, hand-held instrument
PI 500, PC service software on-site
• Gas type (air, nitrogen, oxygen, argon and so on) freely adjustable via PC service software or external device DS 400, DS
500, PI 500
• Reference conditions °C and mbar/hPa freely adjustable
• Zero-point adjustment, leak flow volume suppression
• Pressure loss negligible
Measuring range VA 570: up to 50 Nm/s, Low Speed version*
up to 92,7 Nm/s, Standard version*
up to 185 Nm/s, Max version*
up to 224 Nm/s, High Speed version*
* Measuring range Nm³ / h for different
pipe diameters and gases, see table
measuring ranges flow
* All measurements related to
DIN 1343 standard conditions 0 ° and
1013 mbar ex works
Accuracy:
accuracy class
(m.v.: of meas. value)
(f.s.: of full scale)
± 1.5 % of m.v. ± 0.3 % of f.s.
on request
± 1.0 % of m.v. ± 0.3 % of f.s.
Accuracy indications: referred to ambient temperature 22 °C
± 2°C, system pressure 6 bar
Repeatability: 0.25 % of m.v. in case of correct mounting (mounting aid, position,
inlet section)
Measuring principle: Thermal mass flow sensor
Response time: t90 < 3 s
Operating temperature
range probe tube/display
unit:
-40...180 °C probe tube
-40...70 °C display unit
-40...120 °C for ATEX version
Adjustment possibilities
via display, external
hand-held meter PI 500,
PC Service Software,
remote diagnosis:
Nm³/h, Nm³/min, Nl/min, l/s, ft/min,
cfm, kg/h, kg/min, inside diameter,
reference conditions ° C/° F,
mbar/hPa, zero point correction, low
flow cut off, scaling Analog output
4 ... 20 mA, pulse/alarm, error codes
etc.
Outputs: Standard: 1 x 4 ... 20 mA analog
output (not electrically isolated), pulse
output, RS 485 (Modbus RTU)
Optional: 2 x 4 ... 20 mA active, Modbus TCP, HART, Profibus DP, Profinet,
M-Bus
Burden: < 500 Ohm
Additional average value
calculation:
for all parameters freely adjustable
from 1 minute up to 1 day, e. g. 1/2
hours average value, average day
value
Protection class : IP 67
Material: Housing aluminium die cast, probe
tube stainless steel 1,4571
Operating pressure: 16 bar, in special version 40 bar
Power supply: 18...36 VDC, 5 W
Approval: ATEX II 2G Ex d IIC T4, DVGW
- AT2E VietNam
- Aucom VietNam
- As-schoeler + Bolte Vietnam
- Aira VietNam
- Autrol Viet Nam
- Ashcroft Vietnam
- AEG Vietnam
- Brook Instrument VietNam
- Bircher VietNam
- Bronkhorst Vietnam
- B & K Vibro VietNam
- Baumuller VietNam
- Beckhoff VietNam
- Burkert Viet Nam
- Brugger Feinmechanik Vietnam
- Badger Meter
- Balluff Vietnam
- BEINAT VIETNAM
- CS Instrument VietNam
- CEIA VietNam
- Comet VietNam
- Cosa+Xentaur
- Dwyer VietNam
- DUNGS VietNam
- Dosatec Vietnam
- EMT-Siemens-VietNam
- Emerson | Rosemount VietNam
- Endress+Hauser VietNam
- ECD Vietnam
- Fox Thermal VietNam
- Fireye VietNam
- Fotoelektrik-Pauly VietNam
- FW MURPHY
- Gastron VietNam
- Grant VietNam
- Intorq VietNam
- Ginice Viet Nam
- Gunther GmbH
- Iba VietNam
- IPF Electronic VietNam
- Keller VietNam
- Krohne VietNam
- Kometer Viet Nam
- Kyowa VietNam
- Keofitt Vietnam
- Kiepe
- Knick VietNam
- Kracht VietNam
- Koganei Vietnam
- Labom VietNam
- HBM VietNam
- Matsushima VietNam
- Medenus Vietnam
- Mark-10 VietNam
- Metone VietNam
- Masibus Vietnam
- Novotechnik Vietnam
- ME-Systeme Vietnam
- Micro-Epsilon Vietnam
- Nireco VietNam
- Ohkura VietNam
- OMC VietNam
- PCI Instrument VietNam
- Pulspower
- Pressure Tech Vietnam
- Qualitest VietNam
- Riels VietNam
- Rotork VietNam
- Reckmann Vietnam
- Redlion VietNam
- Rietschoten Vietnam
- UNIPULSE VIETNAM
- Pavone Sistemi VietNam
- Schenck Process
- Sauter VietNam
- Schubert - Salzer VietNam
- Sitec VietNam
- STI Vibration Viet Nam
- Spohn & Burkhardt Vietnam
- Cmovalves Vietnam
- Tokyo Keiki VietNam
- TDK Lambda VietNam
- Tempsens VietNam
- Tema VietNam
- Takenaka VietNam
- Tantronic VietNam
- Tek-trol VietNam
- Taihei Boeki Vietnam
- Vandergraff VietNam
- VORTEX GENIE II / USA
- Vibro-Meter Viet Nam
- VEGA
- Wise VietNam
- Metone VietNam
- Cemb Vietnam
- Okazaki Việt Nam
- Orbinox Vietnam
- Helukabel Vietnam
- Jinda Vietnam
- Hillmar Vietnam
- DMN-WESTINGHOUSE
- Clyde Pneumatic Conveying Vietnam
- Van vòm
- Romer Fordertechnik Vietnam
- Maxcess Vietnam
- R. M.Young Company Vietnam
- VELJAN Vietnam
- HiFlux Filtration Vietnam
- Bush & Wilton Vietnam
- Elau | Schneider Electric
- Magtrol Vietnam
- Rechner Vietnam
- Tester Sangyo Vietnam
- Sensy Vietnam
- IDM Instruments Vietnam
- Hansford Sensors Vietnam
- Hirose valves Vietnam
- Utilcell Vietnam
- Rathicouplings
- Deublin Vietnam
- Ringspann Vietnam
- Nippon Gear
- JNC Valve Vietnam
- GÜNTHER Heisskanaltechnik GmbH
- ID Insert Deal Vietnam
-
Trực tuyến:43
-
Hôm nay:28063
-
Tuần này:28063
-
Tuần trước:96578
-
Tháng trước:96578
-
Tất cả:5461752
-
Đồng hồ đo lưu lượng hơi nước
Ứng dụng phương pháp đo kiểu Vortex.
-
Đồng hồ đo lưu lượng khí | Thermal mass flow sensor for flow measurement
Đồng hồ đo lưu lượng khí | Thermal mass flow sensor for flow measurement
Ứng dụng theo dõi mức tiêu thụ và phân tích dòng rò rỉ của khí chỉ với một thiết bị đo duy nhất.
-
Hệ thống EPC (Edge Position Control) & CPC (Center Position Control)
-
Hệ thống điều khiển, thu thập và phân tích dữ liệu IBA
Hệ thống điều khiển, thu thập & phân tích dữ liệu IBA